0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HTFS 800-P/SP2

HTFS 800-P/SP2

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    SENSOR CURRENT HALL 800A AC/DC

  • 数据手册
  • 价格&库存
HTFS 800-P/SP2 数据手册
Current Transducer HTFS 200..800-P/SP2 For the electronic measurement of currents : DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 200-400-800 A All Data are given with a RL = 10 kΩ Electrical data Primary nominal Primary current Type current rms measuring range IPN (A) IPM (A) 200 400 800 ± 300 ± 600 ± 1200 HTFS 200-P/SP2 HTFS 400-P/SP2 HTFS 800-P/SP2 VOUT Output voltage (Analog) @ IP IP = 0 VREF Reference voltage1) - Output voltage VREF Output impedance VREF Load impedance RL Load resistance ROUT Output internal resistance Capacitive loading CL Supply voltage (± 5 %) VC Current consumption @ VC = 5 V IC RoHS since datecode 45326 45060 45060 VREF ± (1.25・IP/ IPN) V VREF ± 0.025 V 1/2VC ± 0.025 V typ. 200 Ω ≥ 200 kW kΩ ≥ 2 < 10 Ω µF < 1 5 V 22 mA Accuracy 2) @ IPN, TA = 25° C εL Linearity error (0 .. 1.5 x IPN) TCVOE Temperature coefficient of VOE @ IP = 0 TCVREF Temperature coefficient of VREF TCV / V Temperature coefficient of VOUT / VREF @ IP = 0 TCVOUT Temperature coefficient of VOUT VOM Magnetic offset voltage @ IP = 0, after an overload of 3 x IPN DC tra Reaction time @ 10 % of IPN Response time to 90 % of IPN step tr di/dt di/dt accurately followed Vno Output voltage noise (DC ..10 kHz) (DC .. 1 MHz) BW Frequency bandwidth (- 3 dB) 3) OUT REF ≤±1 ≤ ± 0.5 ≤ ± 0.3 ≤ ± 0.01 ≤ ± 0.2 % of IPN % of IPN mV/K %/K mV/K ≤ ± 0.05 % of reading/K < ± 0.5 100 < 15 < 40 DC .. 50 % of IPN µs µs A/µs mVpp mVpp kHz General data TA TS m and secondary circuit • Low power consumption • Single power supply +5V • Ratiometric offset • TA = -40..+105 °C • Isolated plastic case recognized according to UL 94-V0. Special Features • PCB fixation by 4pins x Ø 1.0 • Small size and space saving • Only one design for wide current ratings range • High immunity to external interference. • VREF. IN/OUT. Applications • Forklift drives • AC variable speed drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) Ambient operating temperature Ambient storage temperature Mass Standard - 40 .. + 105 °C - 40 .. + 105 °C 60 g EN 50178: 1997 Notes : 1) It is possible to overdrive VREF with an external reference voltage between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA. 2) Excluding offset and Magnetic offset voltage. 3) • Hall effect measuring principle • Galvanic isolation between primary Advantages Accuracy - Dynamic performance data X Features Small signal only to avoid excessive heatings of the magnetic core. • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications. Application domain • Industrial. Page 1/3 120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer HTFS 200..800-P/SP2 Isolation characteristics Vb Rated isolation voltage rms with following conditions - Over voltage category III - Pollution degree 2 - Non-uniform field Vd Ve Vw dCp dCl CTI Rms voltage for AC isolation test, 50 Hz, 1 min Partial discharge extinction voltage rms @ 10pC Impulse withstand voltage 1.2/50 µs Creepage distance Clearance distance Comparative tracking index (Group IIIa) 2.5 > 1 4 > 4 > 4 > 220 kV kV kV mm mm If insulated cable is used for the primary circuit, the voltage category could be improved with the following table : Cable insulation (primary) Category HAR 03 300V CAT III HAR 05 400V CAT III HAR 07 500V CAT III Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HTFS 200..800-P/SP2 (in mm. 1 mm = 0.0394 inch) Ip 0.5 33 R3 40 16.5 20.3 3 33 d22 26 16 5 3-P=2.54 4 1 4-d=1.0 3.5+/-1 4-0.25x0.5 7 Required Connection Circuit Terminal Pin HTFS 4 2 0V 1 Vref(IN/OUT) Vref(IN/OUT) 3 Output 4.5 Output 47nF +5V 4.7nF 47nF 1...+5V 2...0V 3...Output 4...Vref(IN/OUT) 0V +5V Operation Principle +Vc Vout Vref.(IN/OUT) 0V Ip Mechanical characteristics • General tolerance • Fixation • Recommended PCB hole • Fastening & connection of secondary • Recommended PCB hole ± 0.2 mm 4 pins x Ø 1.0 Ø 1.2 mm 4 pins 0.5 x 0.25 Ø 0.7 mm Remarks • VOUT is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed 120°C. Page 3/3 120202/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
HTFS 800-P/SP2 价格&库存

很抱歉,暂时无法提供与“HTFS 800-P/SP2”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HTFS 800-P/SP2
  •  国内价格
  • 1+577.69720
  • 6+563.56562
  • 12+561.56617

库存:81